GPN1-40.5kV Dipindhah AC Metal-klambi Switchgear Tertutup
Ringkesan
GPN1-40.5kV dipindhah AC metal-klambi switchgear (singkatan kanggo switchgear minangka ngisor) ditrapake kanggo 40.5kV, 3 phase, AC lan 50/60Hz jaringan daya listrik kanggo nampa lan nyebarake energi daya lan uga kanggo kontrol, monitor lan pangayoman.Iki ditrapake ing sistem daya umum lan ing acara sing kerep digunakake.Produk kasebut selaras karo GB 3906 "3~35kV AC Metal Enclosed Switchgear", GB/T 11022 "The common technical clauses of High Voltage Switchgear and Controlgear Standard", DL/T 404-1997 "Order Technical terms of Indoor AC High Voltage Switchgear". lan IEC-298 "1~52kV AC Metal Enclosed Switchgear lan Controlgear standar".
Kondisi Lingkungan
Suhu sekitar: -25 ℃ ~ + 45 ℃, rata-rata saben dina: ≤35 ℃
Dhuwur: 1000m (Standar);bisa nganti 4500m kanggo pesenan khusus;
Kelembapan relatif: rata-rata saben dina ≤ 95%, rata-rata saben wulan ≤ 90%;
Intensitas lindhu≤8 derajat;
Acara sing ditrapake kudu bebas saka korosif, inflammables lan uap.
Model
Fitur Produk
Switchgear minangka unit perakitan lan pemutus sirkuit nganggo model lantai gerobak.Nduwe mung owah-owahan lan uga ijol-ijolan sawise nglengkapi pemutus sirkuit vakum insulasi komposit majeng.Mekanisme propulsi kacang meneng timbal dipasang ing pigura handcart kanggo nyegah saka operasi fault lan mekanisme propulsi ngrusak, handcart bisa dibusak gampang;Kabeh langkah operasi bisa ditindakake ing kondisi nutup;Iku ngunci wajib antarane ngalih utama, handcart lan lawang panel kanggo ketemu limang pangayoman;papan sing amba kanggo nyambungake sawetara kabel ing cubicle kabel.Earthing switch digunakake ing earthing lan daur ulang short circuit, tingkat pangayoman saka pager IP3X, IP2X ing kondisi mbukak.
Spesifikasi Teknis
Ora. | Item | Unit | data | |
1 | voltase dirating | kV | 36/38/40.5 | |
2 | Rated saiki | A | 1250, 1600, 2000, 2500 | |
3 | Frekuensi dirating | Hz | 50/60 | |
4 | Rated short circuit breaking saiki | kA | 25, 31.5 | |
5 | 4s dirating wektu cendhak tahan saiki | kA | 25, 31.5 | |
6 | Rated short circuit nggawe arus (puncak) | kA | 63, 80 | |
7 | Rated peak tahan arus (puncak) | kA | 63, 80 | |
8 | Tingkat insulasi | Rated kilat impuls tahan voltase | kV | 185 (liwat kontak mbukak: 215) |
Sirkuit utama 1min frekuensi daya tahan voltase | kV | 95 (ing kontak mbukak: 110) | ||
Sirkuit tambahan 1min frekuensi daya tahan voltase | kV | 2 | ||
9 | Ukuran garis (W)*(D)*(H) | mm | 1400/2800/2600 (jinis GPN1) 1200/2600/2400 (Kanggo jinis VD4/HD4) | |
10 | Gelar pangayoman | IP3X (kompartemen IP2X) | ||
11 | Bobot | kg | 1000-1850 (tipe GPN1) 850-1850 (Kanggo jinis VD4/HD4) |
Fitur Struktur
Switchgear dibagi dadi enclosure lan handcart, enclosure digawe saka aluminium-seng dilapisi sheet baja sawise diproses dening mesin CNC lan multi-mlengkung, banjur dirakit karo bolts.Dadi wis kekuatan mechanical kuwat lan bisa njamin neatness lan katon apik.Iki kalebu kompartemen relay, kompartemen gerobak, kompartemen kabel, gelar proteksi yaiku IP2X nalika gerobak CB mbukak lan posisi tes.
Switchgear minangka jinis sing bisa dicopot nganggo logam, sirkuit utama nggunakake pangolahan insulasi komposit, nyebarake darurat menyang bagean liyane.CT lan earthing switch dipasang ing kompartemen kabel lan kompartemen busbar.Gelar proteksi pager yaiku IP3X, proteksi lan papan gedhe kanggo sawetara kabel.Desain struktural VCB utawa SF6 CB terisolasi anyar lan mekanisme operasi spring minangka model konsol terpadu kanthi ijol-ijolan sumur sing apik lan mung diganti.