ACB lan MCCB
Ringkesan
GPU1/2/3 Series smart universal air circuit breaker dirancang produk dikembangaké dening kita, voltase dirating saka AC 50/60Hz, 480V (690V), dirating saiki 200A ~ 6300A, utamané digunakake kanggo distribusi daya lan sirkuit pangayoman kanggo distribusi daya jaringan, nyegah sumber daya lan peralatan electrical karusakan saka fault saka kakehan gedhe banget, short-circuit, fault bumi, etc. Wis dhuwur tliti pangayoman Milih lan nambah linuwih saka sumber daya.Breaker uga nduweni fungsi isolasi, cocog karo standar GB 14048.2, IEC 60947-2
Fitur
1. Struktur kompak
2. Ora flashover kadohan High safety
3. Kapasitas dhuwur saka On-Off
4. Smart jinis pangayoman trip liwat-saiki, karo antarmuka komunikasi, Bisa kontrol dening cluster komputer, temen maujud fungsi remot.
5. Tampilan fungsi ammeter, voltmeter
6. Munggah lan mudhun mlebu ora bakal mengaruhi kinerja produk
Model
GPU3 | Pemutus sirkuit udara universal |
1600 | Shield pigura saiki |
4 | 3 3-phase ora tandha 4 4-Fase |
3M jinis kontrol pinter | pengontrol cerdas Tipe 2M: Tampilan tabung digital, nyetel tombol, 3 bagean kanthi fungsi proteksi kesalahan earthing Tipe 3M: tampilan LCD, nyetel tombol, 3 bagean kanthi fungsi proteksi kesalahan earthing Jinis 3H: tampilan LCD, tombol nyetel lan kanggo komunikasi, 3 bagean karo fungsi proteksi kesalahan earthing. |
Cara pemasangan | Tipe tarik-metu Jinis tetep |
Nyambung cara | Kabel horisontal kabel vertikal Wiring ngarep piring-mburi |
Pilihan aksesoris | Under-voltase tripper Interlock mekanik: 2 set utawa 3 set breaker ing tuas vertikal interlocked 2 set breaker horisontal utawa vertikal interlocked dening kabel baja Posisi kunci "Bukak" (kunci kunci) Ngalih 3 posisi tarik Transformator fase N konektor eksternal |
Ing=630 | Rated saiki (A) |
Cathetan:
1. Pengontrol cerdas yaiku jinis M;Ngalih tambahan: 4 kontak kelompok, Cara sambungan ing horisontal.
2. Smart controller, piranti release shunt, cedhak elektromagnetik, mekanisme motor drive lan ing-voltase tripper bakal kasebut Nilai voltase nalika pesenan.
Tabel Pemilihan Teknis
Jinis | Tegangan kerja Rated Ue(V) | Rated insulating tegangan Ui(V) | Rated impulse tahan tegangan Uimp (V) | Pigura tameng saiki Inm (A) | Rated saiki Inm (A) | Nomer fase |
GPU1-1250 | AC400 AC690 | AC690, AC1000 | 12000 | 1250 | 200, 400,630, 800,1000, 1250 | 3, 4 |
GPU1-2000 | 2000 | 630, 800, 1000, 1250, 1600, 2000 | ||||
GPU1-3200 | 3200 | 2000, 2500, 3600, 4000 | ||||
GPU1-6300 | 6300 | 4000, 5000, 6300 |
Kapasitas rusak sirkuit cendhak | Dirating short-time tahan saiki Icw (kA)/1s | Kinerja operasi | |||||
Kapasitas putus hubung singkat maksimal Icu (kA) | Rated running short-circuit breaking capacity Ics (kA) | Umur mekanik (wektu) | Urip listrik (wektu) | ||||
400V | 690V | 400V | 690V | 400V | 690V | ||
50 | 42 | 42 | 15000 | 6000 | |||
80 | 50 | 50 | 40 | 50 | 40 | 15000 | 10000 |
100 | 65 | 80 | 50 | 80 | 50 | 12000 | 8000(5000) |
120 | 75 | 100 | 65 | 100 | 65 | 3000 | 1000 |
GPM11 Moulded Case Circuit Breaker
GPM11Z Smart Molded Case Circuit Breaker
Ringkesan GPM11/GPM11Z
Pemutus sirkuit kasus cetakan seri GPM11 cocok kanggo AC 50 / 60Hz voltase kerja 400V / 630V, saiki nganti 800A jaringan distribusi daya kanggo distribusi sirkuit listrik lan proteksi, sumber daya lan peralatan listrik nglawan kakehan, kurang voltase lan beboyo short circuit, iku mbenakake linuwih sumber daya ing kahanan nggunakake normal kang ora kerep miwiti minangka konversi baris arang lan motor.Lan kanthi fungsi isolasi uga.Iki cocog karo standar GB / T 14048.2 lan IEC 60947-2.
Model
GPM11GPM11Z | Molded Case Circuit BreakerSmart Molded Case Circuit Breaker |
100 | Shield pigura saiki |
H | Kapasitas putus hubung singkat:N: Tipe normal S: Tipe standarH: Tipe putus dhuwur |
P | Cara operasi: Operasi bermotor: Pegangan PRotate operate: Operasi ZDirect (tanpa kode) |
2 | Fitur proteksi Pilihan: proteksi distribusi: ora ana kode Proteksi motor: 2 |
4 | Fase nomer 2: rong fase3: telung fase4: papat fase |
208 | Cara trip lan kode aksesoris internal |
Ing=100 | Rated saiki (A) |
B | 4 Phase breaker N phase duwe 4 macem-macem jinis ditandhani minangka A, B, C, DA: N phase ora bakal nginstal tripper saiki, lan N disambungake tansah, ora dilakokno karo 3 phase liyane.B: N phase ora nginstal tripper saiki, lan N phase ora dilakokno karo 3 phase liyane.C: N phase diinstal tripper saiki, lan N phase dilakokno karo 3 phase liyane.D: N phase diinstal tripper saiki, lan N phase disambungake tansah, Ora dilakokno karo liyane 3 fase. |
Q | Cara Wiring: Ngarep kabel plate: QR mburi kabel plate: HKabel tipe plug-in: R |
Cathetan: 1. Cara Wiring: mburi wiring plate (400, 630s 4P tanpa iku);kabel tipe plug-in (4P tanpa iku)
2. Aksesoris internal dipasang ing sisih kiwa pemutus.
Tabel pilihan technical kanggo GPM11Z MCCB
Jinis | Tegangan kerja Rated Ue(V) | Rated insulating tegangan Ui(V) | Rated impuls tegangan tahan Uimp (V) | Pigura tameng saiki Inm (A) | Rated saiki Inm (A) | Nomer fase | Kapasitas rusak sirkuit cendhak | Dirating wektu cendhak tahan saiki Icw (kA) 1s | Kinerja operasi | ||
Kapasitas putus hubung singkat maksimal Icu (kA) | Rated running short-circuit breaking capacity Ics (kA) | Umur mekanik (wektu) | Urip Listrik (wektu) | ||||||||
GPM11Z-100 | AC400 | AC690 | AC8000 | 100 | 32, 100 | 3,4 | 65 | 50 | 1 | 20000 | 8000 |
GPM11Z-225 | 225 | 225 | 65 | 50 | 2.5 | 20000 | 8000 | ||||
GPM11Z-400 | 400 | 400 | 65 | 50 | 5 | 15000 | 7000 | ||||
GPM11Z-630 | 630 | 630 | 65 | 50 | 8 | 10000 | 7000 |
Tabel pilihan teknis kanggo GPM11 MCCB
Jinis | Tegangan kerja Rated Ue | Tegangan isolasi Rated Ui | Rated impuls tahan voltase Uimp | Kelas pigura dirating saiki Inm A | Rated saiki In (A) | Nomer fase | Dirating max short-circuit breaking kode kapasitas | Dirating max singkat - kapasitas breaking sirkuit | Rated running short-circuit breaking capacity Ics (kA) | Tipe piranti trip | Kinerja operasi (wektu) | |
Urip | Ora-Urip | |||||||||||
GPM11-63 | 400, 690 | 800, 1000 | 8 | 63 | 10, 16, 20, 25, 32, 40, 50, 63 | 3 | N | 10 | 5 | Panas elektromagnetik | 3000 | 7000 |
3,4 | S | 25 | 18 | Panas elektromagnetik | ||||||||
3,4 | H | 50 | 35 | Panas elektromagnetik | ||||||||
GPM11-100 | 100 | 16, 20, 25, 32, 40, 50, 63, 80, 100 | 3 | N | 35 | 25 | Panas elektromagnetik | 3000 | 7000 | |||
3,4 | S | 50 | 35 | Panas elektromagnetik | ||||||||
3,4 | H | 65 | 50 | Panas elektromagnetik | ||||||||
GPM11-160 | 160 | 100, 125, 140, 160 | 3 | N | 35 | 25 | Panas elektromagnetik | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Panas elektromagnetik | ||||||||
3,4 | H | 65 | 50 | Panas elektromagnetik | ||||||||
GPM11-225 | 225 | 100, 125, 140, 160, 180, 200, 225 | 3 | N | 35 | 25 | Panas elektromagnetik | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Panas elektromagnetik | ||||||||
3,4 | H | 65 | 50 | Panas elektromagnetik | ||||||||
GPM11-250 | 250 | 100, 125, 140, 160, 180, 200, 225, 250 | 3 | N | 35 | 25 | Panas elektromagnetik | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Panas elektromagnetik | ||||||||
3,4 | H | 65 | 50 | Panas elektromagnetik | ||||||||
GPM11-400 | 400 | 225, 250, 315, 350, 400 | 3 | N | 35 | 25 | Panas elektromagnetik | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Panas elektromagnetik | ||||||||
3,4 | H | 65 | 50 | Panas elektromagnetik | ||||||||
GPM11-630 | 630 | 400, 500, 630, 630, 700, 800 | 3 | N | 35 | 25 | Panas elektromagnetik | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Panas elektromagnetik | ||||||||
3,4 | H | 65 | 50 | Panas elektromagnetik | ||||||||
GPM11-800 | 800 | 630, 700, 800 | 3,4 | S | 50 | 35 | Panas elektromagnetik | 1000 | 4000 | |||
3,4 | H | 65 | 50 | Panas elektromagnetik |